Industrial Water Chillers

Offered by us are Industrial Water Chillers that are cost effective as these require almost negligible maintenance after these are installed at different places. The Industrial Water Chillers that we deal in is based on the principle which says that a machine ideally performs at optimum load conditions and in this condition we exploit the machine’s efficiency as much as possible.

RO System

Customers can avail from us RO System that is widely demanded in different parts of the country. The RO System that we manufacture as well as supply caters to the varied needs of industrial, domestic and commercial sector that includes offices, homes, hospitals, public places, bus stops, etc. The RO System that we offer to the clients are tested on different parameters and then delivered to the far flung areas of the country. Also, we are the foremost Manufacturer of RO System.

Stainless Steel Water Coolers

Offered by us are Stainless Steel Water Coolers that are demanded by households, public places, corporate houses and other such places. The Stainless Steel Water Coolers that we manufacture are free from any kind of leakage and can be easily cleaned as and when required. We also manufacture water coolers equipped with purifiers.

Water Heating and Cooling System

We offer Water Heating and Cooling System that is known for its excellent performance along with longevity. The Water Heating and Cooling System bring repeated orders from the customers along with their huge appreciation. Furthermore, the Water Heating and Cooling System can be availed at pocket friendly prices.

Technical Specifications of TCD 1000

Parameter Unit Tank 1 Tank 2
Water Heating Capacity L/HR - 100
Water Cooling Capacity L/HR 100 -
Power in put (per hour) Kw 1.25 -
No. of units No 1 -
Total Cooling/heating capacity L/HR 200 -
Total power input (per hour) KW 1.25 -
Water inlet temp. (Approx) oC 30 30
Water outlet temp(Approx) oC 5~15 50-60
Water volume to be Cooled/heated Litres 1000 1000=2000
Cooling/heating time for 2000Ltrs Hrs. 10 hrs. -
Total Energy Consumption(With20% wastage) Rs/Hr 10.5 -
Power tariff (assumed) Rs. 7 -
Operating cost for Cooling&Heating 2000Ltrs. Rs 105 -
Max .Output Hot water Temp. oC 50-60 -
Min. output cool water Temp oC 5~15 -
Operating temp range(Ambient) oC 10’~50 -
Material - - Stainless steel
Therm `O’ chill foot print Sqmt 0.5 -


Technical Specifications of TCD 2000

Parameter Unit Tank 1 Tank 2
Water Heating/Cooling Unit Model TCD 2000 -
Water Heating Capacity L/HR 200
Water Cooling Capacity L/HR 200 -
Power in put (per hour) Kw 2.5 -
No. of units No 1 -
Total Cooling&heating capacity L/HR 400 -
Total power input (per hour) KW 2.5 -
Water inlet temp. (Approx) oC 30 30
Water outlet temp(Approx) oC 5~15 50-60
Water volume to be Cooled&heated Litres 2000 2000=4000
Cooling/heating time for 4000Ltrs Hrs. 10 hrs. -
Total Energy Consumption(With20% wastage) Rs/Hr 21 -
Power tariff (assumed) Rs. 7 -
Operating cost for Cooling&Heating 4000Ltrs. Rs 210 -
Max .Output Hot water Temp. oC 50-60 -
Min. output cool water Temp oC 5~15 -
Operating temp range(Ambient) oC 10’~50 -
Material - - Stainless steel
Therm `O’ chill foot print Sqmt 0.5 -


Technical Specifications of TCD 5000

ParameterUnitTank 1Tank 2
Water Heating CapacityL/HR500
Water Cooling CapacityL/HR500-
Power in put (per hour)Kw6.25-
No. of unitsNo1-
Total Cooling&heating capacityL/HR1000-
Total power input (per hour)KW6.25-
Water inlet temp. (Approx)oC3030
Water outlet temp(Approx)oC5~1550-60
Water volume to be Cooled&heatedLitres50005000=10,000
Cooling/heating time for 10,000LtrsHrs.10 hrs.
Total Energy Consumption(With20% wastage) Rs/Hr52.5
Power tariff (assumed)Rs.7
Operating cost for Cooling&Heating 10,000Ltrs.Rs525
Max .Output Hot water Temp.oC50-60
Min. output cool water TempoC5~15
Operating temp range(Ambient)oC10’~50
Material--Stainless steel
Therm `O’ chill foot printSqmt0.5-


Comparison between TCD-1000 and other commonly used heating/cooling systems

Water ConsumptionLiters1000[hot]1000[cold]
Water inlet TemperatureoC3030
Water Outlet TemperatureoC50 to 6010


ParameterUnitDiesel BoilerElectric GeyserSolar HeaterTherm’O’ChillTMTCD-1000
Energy Consuption /dayLts (or)Kwh10484815
Power / Fuel RateRs.45777
Operating Cost / dayRs.450336336105
No. of days used in a yearDays365365*115365
Operating Cost / Year(Heating)Rs.1642501215453864038325
Energy Consunption / day for 100 lts water coolers X10 Nos working 5 hrs per dayKwh404040-
Operating Cost / year (Cooling)Rs.102200102200102200-
Net Operating Cost / YearRs.26645022374514084038325
Saving / Year if TCD is usedRs.228125185420102515-


To enquire about the desired product(s), just check the box and then click “Inquiry Now” button which is provided below.


  • Water Heating and Cooling System (Power Saving upto 80 %)
    Features
    • Absorbs atmospheric heat
    • Transfer that heat to the water
    • No power consumption for heat generation

    Appreciated For
    • High efficacy
    • Easy installation
    • Direct heating
    • Compact design
    • Eco-friendliness
    • Low operating cost
    • Saving up to 80% power
  • Water Heating & Cooling System (Power Saving upto 70-80%)
    Compact Water Heating & Cooling System provides unimaginable power saving (up to 70 to 80%). A single Water Heating & Cooling System is able to provide 5oC to 15oC chilled water (500 liters per day to 5000 liters per day) and 50oC to 60o hot water (500 liters per day to 5000 liters per day) in two separate tanks at the same time using no extra power. Water Heating & Cooling System can be used for providing drinking water and bathing water from a single machine. The drinking water tank can be provided with R.O./U.V. Purifiers. The Water Heating & Cooling System is ideal for hotels, hostels, hospitals, and other public places with drinking water and bathing facility.